Skip to main content

Kingspan Jindal

Welcome to Kingspan Jindal

TECHNICAL INFORMATION

Comprehensive technical information for QuadCore AWP Wall Panel, including dimensions, thermal performance, certifications, materials, coatings, tolerances, and installation details.

Applications

QuadCore AWP panels are designed for exterior wall applications. Horizontal panels would need vertical steel framing members, whereas vertical panels would need horizontal steel framing members. The steel framing members must span floor to floor or bay to bay of the building, depending on the panel’s orientation.

Available Lengths

Note- * additional costs and transport restrictions may be applicable for non-standard lengths. All lengths may subject to change for export (outside of India).

Available Lengths
Length TypeMeasurement
Standard Length2.0 to 12.0m
Longer Length*upto 15m
Shorter Length*Below 2.0m
Dimensions, Weight & Thermal Performance

Above values are based on declared thermal conductivity at 10°c mean temperature.

Dimensions, Weight & Thermal Performance
Property50 mm60 mm80 mm100 mm
Core Thickness (mm)506080100
U-Value (W/m2 K)0.360.300.230.18
R-Value (m2K/W)2.783.334.445.56
Weight (kg/m2) 0.5/0.5 steel10.5810.9811.7812.58
Insulation Core

Kingspan Jindal QuadCore AWP Wall Panel is manufactured with a HCFC, CFC and HFC free QuadCore insulation core. The core is auto adhesively bonded to the external and internal faces during manufacturing, providing strength and rigidity to the panels.

Certification and Testing

Please contact Kingspan Jindal Technical Team for more data on project specific requirements.

Environmental

Kingspan Jindal insulated panels play a direct role in earning Green Building credits by being certified as IGBC GreenPro product, specifically in the category of Building Insulation Materials.

Air Leakage

Please contact Kingspan Jindal Technical Team for more data on project specific requirements.

Acoustic

Please contact Kingspan Jindal Technical Team for more data on project specific requirements.

Material substrate

Metallic coated steel conforms to IS 15961 : 2012. Please contact Kingspan Jindal Technical Team for information on other substrates.

Paint coatings - External weather steel skin

SMP, SDP and PVDF paint coatings as per IS 15965 : 2012.

Paint coatings - Internal liner steel skin

SMP, SDP and PVDF paint coatings as per IS 15965 : 2012.

Seals

Factory applied side joint seals. All side joints have a factory applied seal fitted into the groove to automatically seal the joint between panels.

Quality & Durability

Kingspan Jindal insulated metal panels are manufactured from high quality materials, using modern production equipment and adhere to quality control standards. They comply with ISO 9001 (Quality), ISO 14001 (Environmental), and ISO 45001 (Health and Safety) standards.

Warranty

Kingspan Jindal Panel Protection warranty covers product finish, structural and insulation performance subject to project specific information provided and materials used. Please contact Kingspan Jindal Technical Team for further information.

Packing

Kingspan Jindal panels are packaged with stretch-wrapped film and EPS blocks underneath for lifting. Bundles have polythene sheets at ends with Kingspan Jindal branding. Pack size varies by panel thickness and profile, limited to 1.2m height. Contact Kingspan Jindal Team for custom packing and trucking details.

Product Tolerance

Note: All dimensions are subject to standard manufacturing tolerances and may vary within acceptable production limits.

Product Tolerance
PropertyTolerance
Length± 5mm
Width± 2mm
Thickness± 2mm
Squareness± 3mm
Flatness (per meter)± 2mm
Fire Performance

Contact Kingspan Jindal Technical Team for more data on the project-specific fire performance of these panels.

Sea Freight

Timber-crated palette skids are available for panel bundles requiring delivery via sea freight shipping, at additional costs.

Delivery

All deliveries (unless indicated otherwise) are made via road transport to the project site. The off-loading process is the responsibility of the client.

Site Installation Procedure

Site assembly instructions are available from Kingspan Jindal Technical Services and should be carried out along with project specific “Good for Construction” drawings issued by Envelope contractor or Kingspan Jindal.

Downloads

Access product brochures, datasheets, and technical documentation to support specification and project planning.

Viewing 1-6 of 9 downloads
kingspan-jindal-quadcore-awp-nfpa-285-brochure.pdf

QuadCore AWP Wall Panel NFPA-285 Brochure

Brochures
Download
kingspan-jindal-quadcore-awp-wall-panel-igbc-greepro-certificate-idr

QuadCore AWP Wall Panel GreenPro Certificate

Certifications
Download
kingspan-jindal-griha-certificate

QuadCore AWP Wall Panel Griha Certificate

Certifications
Download
kingspan-jindal-quadcore-awp-wall-panel-product-data-sheet-en-in.pdf

QuadCore AWP Wall Panel Data Sheet

Data Sheets
Download
kingspan-jindal-quadcore-awp-wall-panel-loadspan-table-en-in.pdf

Quadcore AWP Wall Panel Span Table

Span Tables
Download
kingspan-jindal-quadcore-awp-wall-panel-technical-drawing-vertical-prime-en-in.pdf

QuadCore AWP Wall Panel Vertical Prime Construction Details PDF

Technical Drawings
Download
Viewing 1-6 of 9 downloads