TECHNICAL INFORMATION
Detailed technical data for QuadCore KingSeam Roof Panel, including thermal performance, fire classification, air tightness, and acoustic properties.
Applications
QuadCore KingSeam insulated standing seam roof panels are designed with secret fix joinery on liner side which allows external side of panels to get mechanically seamed on site to adjacent panel along with specially engineered stainless steel clips to provide desired wind uplift resistance. Panels can be fixed to conventional HR purlins and cold-formed steel sections. It is suitable for new and retrofit applications across commercial, industrial, and institutional market sectors.
Available Lengths
Note- *Additional costs and transport restrictions may be applicable for non-standard lengths.
All lengths may subject to change for export (outside of India).
| Standard Length | 2.0 to 10.0m |
|---|---|
| Shorter Length* | Below 2m |
Dimensions, Weight & Thermal Performance
Above values are based on declared thermal conductivity at 10oC mean temperature.
| Core Thickness (mm) | 50 | 83 |
|---|---|---|
| Overall Thickness (mm) | 51-52 | 84-85 |
| U-Value (W/m2 K) | 0.34 | 0.21 |
| R-Value (m2K/W) | 2.92 | 4.75 |
| Weight (kg/m2) 0.5/0.5 steel | 10.29 | 11.61 |
Insulation Core
QuadCore is Kingspan’s next generation hybrid microcell insulation technology. QuadCore is environmentally sustainable, with zero ozone depletion potential and free from CFC/HCFC. The core is auto adhesively bonded to the external and internal faces during manufacturing, providing strength and rigidity to the panels.
Certification and Testing
Please contact Kingspan Jindal Technical Team for more data on project specific requirements.
Environmental
Kingspan Jindal insulated panels play a direct role in earning Green Building credits by being certified as IGBC GreenPro product, specifically in the category of Building Insulation Materials.
Air Leakage
Please contact Kingspan Jindal Technical Team for more data on project specific requirements.
Acoustic
Please contact Kingspan Jindal Technical Team for more data on project specific requirements.
Material substrate
Metallic coated steel conforms to IS 15961 : 2012. Please contact Kingspan Jindal Technical Team for information on other substrates.
Paint coatings - External weather steel skin
SMP, SDP and PVDF paint coatings as per IS 15965 : 2012.
Paint coatings - Internal liner steel skin
SMP, SDP and PVDF paint coatings as per IS 15965 : 2012.
Seals
Site-applied weather and air seals.
Quality & Durability
Kingspan Jindal insulated metal panels are manufactured from high quality materials, using modern production equipment and adhere to quality control standards. They comply with ISO 9001 (Quality), ISO 14001 (Environmental), and ISO 45001 (Health and Safety) standards, ensuring reliability and service life.
Warranty
Kingspan Jindal Panel Protection warranty covers product finish, structural and insulation performance subject to project specific information provided and materials used. Please contact Kingspan Jindal Technical Team for further information.
Packing
Kingspan Jindal panels are packaged with stretch-wrapped film and EPS blocks underneath for lifting. Bundles have polythene sheets at ends with Kingspan Jindal branding. Pack size varies by panel thickness and profile, limited to 1.2m height. Contact Kingspan Jindal Team for custom packing and trucking details.
Product Tolerance
Note: All dimensions are subject to standard manufacturing tolerances and may vary within acceptable production limits.
| Length | ± 5mm |
|---|---|
| Width | ± 2mm |
| Thickness | ± 2mm |
| End Squareness | ± 3mm |
Fire Performance
Contact Kingspan Jindal Technical Team for more data on the project-specific fire performance of these panels.
Sea Freight
Timber-crated palette skids are available for panel bundles requiring delivery via sea freight shipping, at additional costs.
Delivery
All deliveries (unless indicated otherwise) are made via road transport to the project site. The off-loading process is the responsibility of the client.
Site Installation Procedure
Site assembly instructions are available from Kingspan Jindal Technical Services and should be carried out along with project specific “Good for Construction” drawings issued by Envelope contractor or Kingspan Jindal.
Downloads
Access product brochures, datasheets, and technical documentation to support specification and project planning.