Download
sandwich panels for wall
Previous
Next

KJ1020 CS Coldwell I & II

Coldwell Insulated panels are unique, tounge and groove joint panels suitable for airtight, panel to panel interlocking that is easy to install and provide an effective seal. Coldwell panels offers a higher thickness of insulation core and are self supporting upto 15 mtrs.

Product Technical Information

.
  •  Suitable for internal partition wall and celings
  • Available in length upto 15 mtr
  • Comprises an insulated core with a steel top sheet and lower sheet
  • Can be easily interated with curtains, doors and windows
  •  Can be easily integrated with the other wall opening arrangements.
  • PUR/PIR, High performance IPN Insulation core
  • Wall applications
  • Core Thickness (Coldwell I)  30, 40, 50, 60, 80 and 100 mm
  • Core Thickness  (Coldwell II)  80, 100, 120, 150, 175 mm
  • Modular width 1020 mm
  • Standard lengths in the range of 12 m 
  • Fixing:  Tounge and Groove interlocking and sealed joints


 

Thermal Performance, Dimension and Weight


Kingspan Jindal KJ1020 CS Coldwell I
                                                                                     Core thickness in mm
Thermal Insulation Minimum Core Thickness  30 40 50 60 80 100
U - Value (W/Sq M K) 0.54 0.46 0.39 0.31 0.25 0.2
R- Value (Sq Metres K/W) 1.85 2.17 2.56 3.23 4.00 5.00
Overall Thickness  30 40 50 60 80 100
Weight (Kg/Sq M )  9.4 9.9 10.5 11 11.7 12.5




 
U value has been calculated using the method required by the appropriate National Building Regulations 


Kingspan Jindal KJ1020 CS Coldwell 2
                                                                                                    Core thickness in mm
Thermal Insulation Minimum Core Thickness  80 100 120 150
U - Value (W/Sq M K) 0.25 0.2 0.15 0.13
R- Value (Sq Metres K/W) 4.00 5.00 6.67 7.69
Overall Thickness  80 100 120 150
Weight (Kg/Sq M )  11.7 12.5 13.5 14.6

 
KJPL_WALLPANEL_PUR_COLDWELL1_40MM_INDIA

System Accessories & Services

Dedicated Technical Support is available throughout the building cycle, pre and post manufacture.

Please contact us for complimentary services including: U value/Condensation risk calculation, project specific NBS specification, bespoke construction details, advice on fire & acosutic performance, panel spans, fastners & roof drainage calculations, optimised lightning designs, building energy modelling and Installation training.

 

Find a product

We use cookies on our website www.kingspanjindal.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click “Accept and close” to accept the use of cookies on our website. If you do not click “Accept and close” but continue to use this website: you thereby consent to the use of all www.kingspanjindal.com cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.